@@ -38,10 +38,14 @@ If sys.gettotalrefcount() is not available (because Python was built without
|
|
|
the Py_DEBUG option), then this module is a no-op and tests will run normally.
|
|
|
"""
|
|
|
|
|
|
-import copy_reg
|
|
|
import gc
|
|
|
import sys
|
|
|
|
|
|
+try:
|
|
|
+ import copy_reg as copyreg #PY26
|
|
|
+except ImportError:
|
|
|
+ import copyreg
|
|
|
+
|
|
|
try:
|
|
|
import unittest2 as unittest #PY26
|
|
|
except ImportError:
|
|
@@ -74,7 +78,7 @@ class ReferenceLeakCheckerTestCase(unittest.TestCase):
|
|
|
# python_message.py registers all Message classes to some pickle global
|
|
|
# registry, which makes the classes immortal.
|
|
|
# We save a copy of this registry, and reset it before we could references.
|
|
|
- self._saved_pickle_registry = copy_reg.dispatch_table.copy()
|
|
|
+ self._saved_pickle_registry = copyreg.dispatch_table.copy()
|
|
|
|
|
|
# Run the test twice, to warm up the instance attributes.
|
|
|
super(ReferenceLeakCheckerTestCase, self).run(result=result)
|
|
@@ -97,8 +101,8 @@ class ReferenceLeakCheckerTestCase(unittest.TestCase):
|
|
|
result.addError(self, sys.exc_info())
|
|
|
|
|
|
def _getRefcounts(self):
|
|
|
- copy_reg.dispatch_table.clear()
|
|
|
- copy_reg.dispatch_table.update(self._saved_pickle_registry)
|
|
|
+ copyreg.dispatch_table.clear()
|
|
|
+ copyreg.dispatch_table.update(self._saved_pickle_registry)
|
|
|
# It is sometimes necessary to gc.collect() multiple times, to ensure
|
|
|
# that all objects can be collected.
|
|
|
gc.collect()
|